The module library includes several pop-up detail displays that can be invoked from the pop-up faceplate (instrument) displays. After the faceplate has been opened by selecting the faceplate icon on the process graphic, the detail display can be opened by selecting the icon in the lower left part of the faceplate. The detail displays, like the faceplates, are located in the DELTAV\DVDATA\GRAPHICS-iFIX\PIC\DETAIL subdirectory. The following faceplates are stored in the DETAIL subdirectory:
|
AALM_dt |
Used by the AALARM monitoring module template. |
|
AI_dt |
Used by the ANALOG monitoring module template. |
|
ALM_FLD_SUP_dt |
Used by the Alarm flood suppression module templates. |
|
ALM_FO_SUP_dt |
Used by the First out alarm suppression module template. |
|
RMT_SPM_dt |
Used by the Rosemount Statistical Process Monitoring module templates. |
|
CDA_dt |
Used by modules with command-driven algorithms |
|
DL_dt0 |
Used by the motor and valve module templates that do not have interlocks (that is, that do not contain _ILOCK in the name). |
|
DL_dt1 DL_dt2 DL_dt3 DL_dt4 DL_dt5 DL_dt6 DL_dt7 DL_dt8 |
Used by the motor and valve module templates that have interlocks (that is, do contain _ILOCK in the name). The difference in these displays is in the number of interlock condition descriptions shown. |
|
DTC_dt |
Used by the PID_DEADTIME module template. |
|
FFLP_dt |
Used with the fieldbus loop module template, FF_PID_LOOP. Similar to Loop_DT. |
|
FLC_dt |
Used with the Fuzzy Logic Control templates, FLC_LOOP and SIM_SR_FLC. Similar to LOOP_DT. |
|
GS_dt |
Used by the PID_GAINSCHED module template. |
|
Loop_dt |
Used by the PID Loop module templates (PID_LOOP, CASCADE_MASTER, CASCADE_SLAVE). |
|
LOOPM_dt |
Used by MPC loop modules |
|
PI_dt |
Used with the PULSE monitoring module template. |
|
PLM_dt |
Phase Logic module detail display. |
|
SDA_dt |
Used by modules with state-driven algorithms. |
|
SR_FLC |
Used by the FLC Simulation module template, SIM_SR_FLC. |
|
SR_PID |
Used by the PID Simulation module template, SIM_SR_PID. |
|
TAGAI_dt |
Tag AI integration module detail display. |
|
TAGAO_dt |
Tag AO integration module detail display. |
|
TAGDI_dt |
Tag DI integration module detail display. |
|
TAGDO_dt |
Tag DO integration module detail display. |
|
UM_dt |
Batch Unit module detail display. |
|
UMC_dt |
Continuous Unit module detail display. |
It is recommended that you use the Update Popup Pictures button on the DeltaV Utilities toolbar if you modify pop-up pictures. Refer to Updating Pop-up Pictures and Dynamos in the topic Working with Pictures - Additional Functions for more information.
The DISCRETE monitoring module template does not have a detail display. All necessary information is incorporated in the faceplate display.