  • CHARMs Smart Logic Solver configuration
    • CSLS SIS systems in DeltaV Explorer
    • Secure parameters in CSLS
    • SIS Controller configuration
    • CHARMs Smart Logic Solver Local Safety Network (LSN)
    • CSLS SIS module execution
    • CSLS redundancy
    • CSLS physical unlock inhibit key
    • CHARMs Smart Logic Solver downloads
    • Use of LS CHARM data in non-SIS modules
    • LS CHARM types
      • LS CHARM Analog input parameters
      • LS CHARM with HART functionality analog input parameters
      • LS CHARM Discrete input parameters
      • LS CHARM thermocouple MV input parameters
      • LS CHARM RTD input parameters
      • LS CHARM Voltage input parameters
      • LS CHARM Power input parameters
      • LS CHARM Discrete output parameters
      • LS CHARM HART two-state output parameters
    • LS CHARM failsafe behavior
    • SIS Controller Modbus port
      • SIS Controller Modbus port write support
    • CHARMs Smart Logic Solver standalone safety systems
    • Bulk editing CHARMs Smart Logic Solver objects
      • Bulk edit CHARMs Smart Logic Solvers
        • CHARMs Smart Logic Solver object syntax table
      • Bulk edit LS CHARMs
        • LS CHARMs object syntax table
      • Bulk edit CHARMs Smart Logic Solver plus LS CHARMs
        • CHARMs Smart Logic Solver plus LS CHARM I/O object syntax table
      • Bulk edit SIS Controller Modbus Port register mapping
        • SIS Controller Modbus Port mapping object syntax table
      • Bulk edit Local Safety Network Bridges
        • LSNB object syntax table
      • Bulk edit Local Safety Network Gateways
        • LSNG object syntax table
      • Bulk edit Local Safety Network Gateway signals
        • LSNG signals object syntax table
  • Version Control and CSLS SIS systems
  • Global Safety Network
    • Local Safety Network Bridge
    • LSNB Ethernet port connections
    • Domains and publishers
    • LSNB secure parameters and references
    • LSNB secure parameter mapping
    • Remapping Global Safety Network secure parameters
    • LSNB configuration
    • LSNB diagnostics
  • Local Safety Network Gateway
    • Local Safety Network Gateway and Modbus devices
      • LSNG publishers
      • Configure the LSNG
      • Configure LSNG Modbus ports
      • LSNG port connections
    • The Autronica BS-420 in a DeltaV system
      • Connect the BS-420 to the DeltaV system
      • Configure the BS-420
      • Configure BS-420 devices in DeltaV Explorer
      • Export the BS-420 configuration
      • Import the BS-420 configuration into DeltaV Explorer
      • Example DeltaV configuration using data from the BS-420
  • Automatic Upgrade of LSNBs and LSNGs
  • SIS CSLS logic checkout using virtual machines
    • SIS CSLS VM scenarios and strategies
      • Scenario: Create a new SIS CSLS system
      • Scenario: Add SIS CSLS hardware that does not interact with existing hardware
      • Scenario: Add SIS CSLS hardware that interacts with existing hardware
    • Create the SIS CSLS virtual system
      • Set up Virtual Networks
      • Create virtual hardware from templates
      • Relate virtual hardware to items in DeltaV Explorer
    • Configure virtual system, test, and move configuration to production system